TURTLE
Turtle 549 Waterproof Pluckable Equipment Case 07-549002
- SKU:
- CASE-T549PL
- UPC:
- 702119679350
- MPN:
- 07-549002
- Condition:
- New
- Availability:
- This item is usually in stock and therefore ships within 24 hours of us receiving the order, unless it is a weekend or public holiday where it will be shipped on the next business day.
- Minimum Purchase:
- 1 unit
Description
The Turtle 549 Waterproof Pluckable Equipment Case 07-549002 is suitable for all large pieces of equipment with its 13mm or 1/2 pluckable foam cubes allows the space to be customised. The Turtle 549 equipment case is air-tight, dustproof, waterproof and ATA certified.
Features:
- Remove foam to create needed space
- Stainless steel hardware
- Double movement latches prevent accidental opening for added protection
- Double padlockable
- Lifetime warranty
- Weight: 4.9 kg's or 10.6 lb
- Inside Dimensions: 55.9 cm x 43.2 cm x 21 cm or 22" X 17" X 8.2"
- Outside Dimensions: 63.5 cm x 50.6 cm x 22.4 cm or 25" X 19.9" X 8.8"
Certifications
Waterproof IPX7
Dustproof IP6X
Impact ATA 300
Drop Test ASTM D-4169 CC-18
Vibration STM D-4169 DC-18
Rainfall ASTM D-4169 DCc-18
Immersion MIL-STD-810F
Descriptions of Tests
ATA Specification 300 Category 1
Airline transport container suitable for a minimum of 100 airline trips
Impact Resistance Test; samples were exposed to impact using a bar weighing 13.2lbs with a hemispherical end of 3.2cm. Bar was dropped with its longitudinal axis vertical on to each sample’s weakest point from a height of 0.5m. Samples were conditioned to a temperature of -20°C before impact exposure.
ASTM D-4169 DC-18
Level 1 Schedule A Handling (Manual)
Drop tests - a series of drops on each edge, corner and face of the case from a height of no less than 48cm(19”) and with loads of 6.8-31.8kg(15-70lbs) determined by case size. Samples were conditioned at lab ambient conditions and then temperatures of -28°C and +60°C for a minimum of 3 hours at each condition.
ASTM D-4169 DC-18
Level 1, Schedule F loose load vibration
Vibration - The cases are tested using test method D-999 to determine the ability to withstand the repetitive shocks occurred during transportation of loose loads.
ASTM D-4169 DC-18
Level 1, Schedule H Environmental Hazard Rainfall
Simulated rainfall for 2hrs at a rate of 10cm/hr (4”). Samples were conditioned to -20 degrees C and +52 degrees C.
MIL-STD-810F
Method 512.4
Immersion - The case is submerged in a basin of water to a depth of 1 meter (3.28 ft) to the top most part of the case for 30 minutes. The case is heated to 10 degrees F higher than the temperature of the water.
IP 67 ingress protection
6- Total protection from dust
7- Protected against the effects of immersion between 15cm (5.9”) and 1m (39.37”)